高达8%返现· This guide covers a wide range of topics related to installing Renogy solar panels from identifying the specifications of your solar panel and selecting a suitable junction box to mechanical and electrical
• Hazardous manual tasks: – handling/moving panels – handling solar panel mounting kits. If you work on solar installations: • plan before accessing the roof • use fall protection • make sure all
1.3 Solar PV Technology 6 Ê Ê UÊ ÀÞÃÌ> i Ê- V Ê> ` Ê/ Ê Ê/iV } iÃÊ n Ê Ê UÊ ÛiÀÃ Ê vwV i VÞÊ n Ê Ê UÊ vviVÌÃ Ê v Ê/i «iÀ>ÌÕÀiÊ 1.4 Technical Information 10 2 Solar PV Systems on a
Installing solar photovoltaic systems requires specialized skills and knowledge. Installation should only be performed by qualified personnel. Before installing a solar photovoltaic system, installers should familiarize themselves with its mechanical and electrical requirements.
The aluminum frame of the PV module shall not be deformed during installation, and the front of the module shall not be covered. Each PV module needs to be fixed with at least four clamp, and the applied torque is 16N · m ~ 20N ·m.
When the solar photovoltaic module is connected in parallel with the bypass diode, the current in the system will flow directly through the diode, so as to bypass the blocked part of the solar photovoltaic module and minimize the heating degree and power consumption of the solar photovoltaic module. Each module has three diodes.
The shadow will cause the loss of the output power of the solar photovoltaic system. Although the bypass diode installed in the solar photovoltaic module can reduce this loss to some extent, do not ignore the shadow factor. Do not install solar PV modules near fire or flammable materials.
PV module are wet.Use insulated tools and d not use wet tools.When installing PV modules, do not drop any objects (e.g., P modules or tools).Make sure flammable gasses are not generated or present near th installation site.Insert module connectors ully and correctly. An audible "click" so
Risen module should be installed in the following environmental conditions. -20°C to+50°C. Remarks: The working environment temperature is the monthly average maximum temperature and minimum temperature of the installation site. The mechanical load bearing capacity of the solar PV module is determined based on the installation method.