In 2016, 1.2 GW of photovoltaic (PV) power tripped off in California during the "Blue Cut Fire" when PV inverters miscalculated the grid frequency during a line-to-line fault.
connected inverter system under unbalanced grid faults to meet fault ride through requirements ISSN 1751-8687 Received on 7th August 2019 Revised 5th May 2020 Accepted on 11th May
Abstract: Fault ride-through specifications listed in modern transmission and distribution grid codes specify that photovoltaic system have to operate under grid faults. In the classic
This study presents a fault detection and isolation (FDI) method for open-circuit faults (OCFs) in the switching devices of a grid-connected neutral-point-clamped (NPC) inverter for photovoltaic (PV)
To estimate the fault current profile on a PV-dominated distribution feeder, the authors in proposed a new method that extends conventional short-circuit analysis methods and provides an estimate of fault
In addition to the three-phase PV inverter, in Gonzalez et al., a single-phase PV inverter (3.2 kVA) is investigated under fault condition when operating with grid-connected functionality. During a fault, the voltage at the
This paper gives an overview of the current state-of-the-art control strategies for handling voltage problems through PV inverters and other devices. (OV), undervoltage,
The paper [22] presents another support scheme for achieving LVRT with a grid-connected PV inverter during fault. But off-grid operation has not been considered. Article [23]
The NPC leg-based inverter is made fault tolerant by incorporating a redundant leg which enables the main inverter to tolerate the open-circuit fault at all fault locations. In,
Accurate fault diagnosis is the premise to ensure the safe and reliable operation of photovoltaic three-level inverter. A fault diagnosis method based on wavelet neural network
New research has categorized all existing fault detection and localization strategies for grid-connected PV inverters. The overview also provides a classification of various component failure
The overall classification accuracy is quantified as 99% for the proposed FDL. An ANN based FDL employing DWT based fault feature mining for grid connected PV inverters is
The ride-through operation of photovoltaic inverter will produce apparent harmonic currents, cause active and reactive power fluctuations as well as DC voltage fluctuation under
There are many PV inverter topologies. Using a low frequency (LF) transformer, standard grid PV inverters are prepared to increase input voltage as shown in Fig.3 (a). LF-transformer is
the post-fault power recovery and voltage support capability can be significantly improved. 1Introduction The photovoltaic (PV) generation is a promising alternative of the conventional
sider the real fault current value reached by PV inverters. The fault current from a PV system also depends strictly on the PV inverter control. Current control mode (CCM) and voltage control
In addition to the three-phase PV inverter, in Gonzalez et al. (2018), a single-phase PV inverter (3.2 kVA) is investigated under fault condition when operating with grid-connected functionality. During a fault, the voltage at the PCC of the single-phase PV inverter also reaches 0.05 pu, and the test results are summarized in Table 7.
Since the two-stage PV inverter has an intermediate DC/DC link, there is a certain voltage difference between the PV module and DC capacitor, and the fault coupling degree of undervoltage is lower than that of overvoltage fault. According to the fault location, the fault causes can be divided into two types: DC short circuit and sampling error.
In these tests, faults are also caused at the PCC of the PV inverter, leading the voltage to reach 0.05 pu. The first ½ cycles fault current ranges from 1 to 1.2 times the pre-fault current (1 pu). By comparing Tables 4 and 6, it can be seen that the PV inverter model investigated in Gonzalez et al. (2018) is in agreement with the generic group.
In addition, the experimental results available in the literature are specific to the PV application. Many works in the literature address the behavior of grid-connected PV inverters under a fault condition. Some of them, specifically, investigate the fault current contribution from this equipment by means of simulations.
In all cases, the fault is caused at the coupling point of the PV inverter, leading the voltage to zero. In addition, it can be seen that the steady-state fault current of the PV inverters is practically the same for different power factor conditions, i.e., from 1 to 1.1 pu of the pre-fault current (1 pu).
There are multiple fault causes coupling in DC side of photovoltaic inverter. The changes of voltage, current and power are derived by fault mechanism analysis. The differences of failure feature are used to locate the fault cause. 1. Introduction