Through the special permutation and combination,Motor Cooler for Megawatt Class Wind Turbine motor can effectively decrease the wind drag, Improve the cooling flow of the motor,add exchange heat rate at the same volume.
After having secured optimum performance for thousands of wind turbines installed onshore or offshore and in all kinds of operating conditions, we have unrivaled expertise with wind turbine cooling solutions. We design and
·The dry cooler is constructed of staggered and seamless copper tubes (15,9 or 12,7 diameter) with aluminium, rippled and corrugated fins (0,14 or 0,17 thickness). ·2,5 mm fin spacing for
Generac Air-Cooled Generator: Around 66-70 dBA at 7 meters (23 feet). Cummins Liquid-Cooled Generator: Around 60-65 dBA at the same distance. The noise level comparison provided
Not Just a Cooling Fan: Featuring a superb honeycomb cooling pad, washable dust filter and anion generator, this evaporative air cooler can turn the hot and dry air into cool and moist air.
There are several ways to achieve this, such as forced air cooling and natural convection. Natural convection uses the airflow around the generator, while forced air cooling uses a fan to blow
To prevent damage to the generator, the heat must be dissipated. To do so, VENSYS relies on a simple yet efficient air cooling method. The generators of the 1.5 MW platform are cooled using a passive, maintenance-free air circulation
The key novelty in this paper is the assessment of the cooling methods based on generator size, reliability and maintenance requirements. Windings made of hollow copper conductors: (a) 8 MW
The hot air after the heat exchange is drawn into the radiator by the inner circulation fan to be cooled by the coolant, and then fed into a sealed cabin, is then filtered into the generator by dehumidification. This completes a cooling cycle. The cooling system cooling process is illustrated in Fig. 2. Fig. 2.
The requirements for generator cooling are: the cooling effect should reach the normal operating temperature range of the generator. The cooling of each part should be uniform, and local overheating should not occur. The structure of the cooling system should be as simple as possible and consume less power.
Cooling Systems for Direct-Drive Generators safety limits, additional hardware must be used for cooling. The har dware can range heat exchangers. The goal of the cooling system is to reduce the machine hotspots below insulation class values and also PM demagnetization temperature. The various cooling hot surface, removing heat from it.
The associated cooling system is therefore crucial to keep the generator and inverter sizes down and to operate within the safe thermal limits. Various cooling techniques suitable for generators are therefore reviewed and analyzed in this paper.
The cooling system is connected to the generator outlet through rubber pipes. Fig. 10. Cooling system test prototype. 2.5 MW PMSG permanent magnet wind turbine is the main wind power generation equipment in Xinjiang. The high temperature rise of the generator is closely related to the ambient temperature, unit running time and power generation.
The liquid-cooled method is mainly pure water or other liquid coolant as the cooling medium [ , , , ], through the generator external liquid cooling tube to achieve heat exchange. This method needs more complex liquid cooling pipe laying, coolant configuration and additional cooling auxiliary equipment.